Servicing a sewer camera? Easy Job

A sewer camera is essential for every repairer, and every repairer wants his sewer camera to be available 24 hours a day. This is where a modular sewer camera becomes very important, as it only needs to be replaced with accessories to make the camera work again. Sanyipace has always adhered to this design principle, as all sewer cameras are modular and easy to use. Each customer can check and complete the repair work independently.

When you have a problem with your sewer camera, how should you do some self-inspection work? How should you determine where the problem is occurring? Follow the article and read on.

What should you do when your sewer camera suddenly becomes blue or black screen? Please don't worry and be anxious. Trust Sanyipace's customer service will patiently explain and provide solutions for you. Please patiently follow the steps below to troubleshoot the problem.

1. Check the power supply

Check whether the electric volts on the screen are lower than 10V. When lower than this value, please charge in time. Because below this value, the device's power can not power the whole machine. It will make some functions appear abnormal or blur the screen.

Note: Do not use the device while charging.

2. Check the camera

  • Check whether the camera is in water or has water droplets
Check whether the camera is in water or has water droplets
  • Check whether the camera lens has fallen off
camera lens has fallen off
  • Check whether the waterproof rubber ring of the camera has been lost
the waterproof rubber ring of the camera has been lost
  • Check whether the camera thimble is broken and no longer flexible
Check whether the camera thimble is broken and no longer flexible

When your camera has any of the above situations, you can judge that it is time to replace the new camera.

3. Check the sewer coil

Check whether the metal ring of the coil is scratched. When the thimble of your camera is broken, 90% of the metal ring will be scratched.
Check whether the sewer coil is broken or breaks.

When your coil has any of the above conditions, you can judge that it is time to replace the new coil.

4. Check the connection cable

Check whether all the cables are connected and try to shake the cable to check if there is a picture on the screen.

If the image appears, it proves that you are not connected to the cable or the cable is broken, so you can replace it with a new one.

If the above 4 cases have been checked without problems, this time, you need to further check the connector of each accessory. Please follow the tutorial below to check which part appears using a multimeter. Of course, I believe you are patient enough to complete each step of the self-checking work because you are a good pipe inspector!

  • Check coil circuit

First, find the connectors and metal ends of the coil. Second, take out your multimeter and point the red pen to the coil connector and the black pen to the metal end. Please follow the instructions in the picture below to test whether the current of each hole is connected. The multimeter will emit a "beep beep" sound if it is connected. Here you need to test 4 holes; all of them can make sound, which proves that the coil is okay. But there is no sound in one of them, proving a problem with the coil.

  • Check the meter counter's circuit board

Find the circuit board of the meter counter from the coil, it is located on the central axis of the coil; it is a disc. Get out your multimeter and the red pen points to the board in the disc, and the black pen points to the other end of the wire. This time you need to test 3 holes, when they all can make a "beep beep" sound, the meter counter circuit board is fine. But if one fails to make a sound, it proves something is wrong. 

Problems with the meter counter generally manifest as the calculated distance is inaccurate or cannot be reset, and the LED light is not on.

  • Check the connection cable

If the connection cable is bad, it will also affect the connection between the coil and the screen. The red pen points to the end of the daughter screw cap, and the black pen points to the end of the female screw cap. This time you need to test 5 holes (5mm diameter coil) or 6 holes (7mm diameter coil). When all can make a "beep beep beep" sound, prove that the connection cable is okay. But one does not make a sound, proving there is a problem.

If you check step by step according to the above tutorial, you can surely find out where the problem is. Then tell Sanyipace customer service the check result, or buy the corresponding model from the website parts list as a replacement.

If you have more questions, don't hesitate to contact us for more information.